Skip to the content
  • 1451 Lake Dr SE, PO Box 6484 Grand Rapids MI 49516
  • +1 (616) 458-6733
  • info@greenhomeinstitute.org
  • Roster of Housing Professionals
Green Home Institute Logo 1
  • Home
  • About
  • Project Consultation
  • Education
  • Events
  • Support GHI
  • Find a Pro
  • Get Involved
  • News
  • Join GHI
  • Contact Us
Menu
  • Home
  • About
  • Project Consultation
  • Education
  • Events
  • Support GHI
  • Find a Pro
  • Get Involved
  • News
  • Join GHI
  • Contact Us
Login / Sign Up
Green Home Institute Logo 1
  • Home
  • About
  • Project Consultation
  • Education
  • Events
  • Support GHI
  • Find a Pro
  • Get Involved
  • News
  • Join GHI
  • Contact Us
Menu
  • Home
  • About
  • Project Consultation
  • Education
  • Events
  • Support GHI
  • Find a Pro
  • Get Involved
  • News
  • Join GHI
  • Contact Us
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
page
member
sponsor
youtube_playlist
events
board_of_directors
staff_support
job
certificationprogram
member
certificationprogram
greenstar_homes
Green Home Institute Logo 1
  • Home
  • About
  • Project Consultation
  • Education
  • Events
  • Support GHI
  • Find a Pro
  • Get Involved
  • News
  • Join GHI
  • Contact Us
Menu
  • Home
  • About
  • Project Consultation
  • Education
  • Events
  • Support GHI
  • Find a Pro
  • Get Involved
  • News
  • Join GHI
  • Contact Us

Vastu Shastra Sanctum GreenStar Silver GHI Zero Energy Certified

Vastu-R-Value-Certified-new-
IMG_0604-scaled
Photo-Mar-11-10-36-04-AM-scaled
1404-Marsman-Ave-SE.-
Photo-Mar-11-10-35-24-AM-scaled
Photo-Mar-11-10-34-38-AM-scaled
Press-Release-Award-2-scaled
  • 13 Apr
  • 2023

Vastu Shastra Sanctum GreenStar Silver GHI Zero Energy Certified

  • / By
  • admin

“The owners of the Vastu Shastra Sanctum gave us a challenge: a net-zero home with radiant floor heat. Net-zero made this goal difficult due to a severe lack of quality equipment from reputable manufacturers. When most people compromise and use a boiler to heat their floors, the R-Value team utilized an American made air-to-water heat pump, just the 5th in the nation.

But that was not the only obstacle to overcome. Due to the Vastu design principles, the team was left with some significant structural elements, that threatened the thermal and air barriers in key places. For many of these, Insulated Concrete Forms were ideal for the task, and R-Value’s extensive experience with ICF’s was the perfect fit.  Every single challenge the project presented was overcome with creativity and determination.

From the designer, to the engineer, the R-Value Homes staff, and every valued Trade Partner of ours: Thank you for stepping up to the plate to make this incredible home a reality for our clients!”

The home is projected to deliver 3,000 kwh’s per year of solar power to the grid, more than what it uses.

Sustainability Features 

  • -10 HERS Index Rating
  • Air-to-water Air Source Heat pump for hydronic heating, forced air cooling, and domestic hot water
  • .65 ACH of air leakage
    Insulated Concrete Form exterior walls (ICFs)
  • Frost Protected Shallow Foundation
  • Polished concrete floors with hydronic heating on both levels
  • Heat Recovery Ventilation exceeding ASHRAE 62.2 2016 Standard
  • Passive Solar Design
  • 100% electrified home
  • Roof-mounted solar PV system is estimated to produce 15 Megawatts a year
  • 27 Kwh Battery System

Check out more photos and details on Houzz

This home and all homes meeting the GreenStar Homes Certification Silver (v3) Feature these items additional green items.

  • Moisture and wall water leak assessment + repair
  • Plumbing leak and pressure test shows no leaks
  • No gas leaks detected after construction / renovations
  • Test for no CO backdrafting from gas appliances
  • No new supply ducts panned in joists
  • Use at least MERV 8 Rated Filters on Ducted Systems
  • Electric stove OR Range Hood tested to vent at 100 CFM outdoors
  • Carbon Monoxide detectors (can be dual smoke) installed on all floors and near fireplaces
  • Use steel braided hoses or drainpans under washers in or above living spaces
  • Drainpans under tank water heaters that are in or above living spaces
  • 90% LEDs used
  • Gutter system draining away from home or well draining sandy soils
  • Bathroom exhaust fans must be tested to at least 50 CFM or more in each bathroom
  • No radon detected above PCL 4 when tested or system installed
  • New HVAC must be properly sized based on manual J/D or equivalent
  • Moisture resistant flooring in bathroom, kitchen & entry ways
  • Whole Home Fresh air supply provided
  • All fireplaces must have proper ventilation per IAP or No fireplace exists
  • Refrigerant charge test completed on all AC / Heat pumps
  • Instructions created documenting how to operate the home or unit
  • New gas appliances must be sealed, vented or ideally electric
  • Homeowner or tenant trained on how to operate the house or unit
  • DOE Home Energy Score of 6
  • Shower head(s) are under 2.0 Gallons Per Minute (Average) or Home Water Score of 3
  • Bathroom Aerators are under 1.75 Gallons Per Minute (Average) or Home Water Score of 3
  • Toilets are under 1.3 Gallons per Flush (average) or Home Water Score of 3
  • Non paper face drywall backer in NEW shower / tub surrounds
  • Don’t use HVAC during construction – Major remodels and new only
  • Insulate hot water lines or have runs 10 feet or shorter to all lines
  • Paint/caulks/sealants/primers must be certified Low VOC or NO VOC
  • Kitchen must have proper ventilation through rangehood or outdoor air system
  • Well water systems must use on demand softeners when present (Gold)
  • Bathroom controls such as timer/occupancy sensor or humidistat (Gold)
  • Balanced fresh air system installed and working
  • Final Grade Slopes Away from Foundation 0.5 inch per foot for 10 feet
  • If installing new wood do not use tropical OR make sure it is certified (gold)
  • Insulate cold water pipes or keep them out of unconditioned space (Gold)
  • DOE Home Energy Score of 10 on existing or 17.5 mbtu/year of energy (Platinum)
  • Water heating is all electric or solar
  • All space heating is electric or solar thermal
  • All water heating is electric or solar thermal
  • No fireplace indoors
  • Indoor air quality test after construction are at or below the WELL Standard.
  • Home breaker box can fit future solar
  • Certified low emitting or sealed edges on new cabinets
  • Floorscore or Green Label Plus on 90% of new Carpet
  • Tap water filtration added that is appropriate to area
  • Shoe removal space with no carpet at main entry
  • Flush out home for 48 hours after construction activity before client move in
  • Add leaf debris filter to gutters
  • No gas or propane hook up connected
  • Induction or electric cooktop
  • Battery storage system
  • Ability to make blue light free lighting in high use rooms
  • Refrigerator has freezer on top or bottom
  • Low duct leakage or no ducts
  • Motion sensor / dimmer lights in high use rooms
  • Energy Star Dishwasher Installed

“The owners of the Vastu Shastra Sanctum gave us a challenge: a net-zero home with radiant floor heat. Net-zero made this goal difficult due to a severe lack of quality equipment from reputable manufacturers. When most people compromise and use a boiler to heat their floors, the R-Value team utilized an American made air-to-water heat pump, just the 5th in the nation. But that was not the only obstacle to overcome. Due to the Vastu design principles, the team was left with some significant structural elements, that threatened the thermal and air barriers in key places. For many of these, Insulated Concrete Forms were ideal for the task, and R-Value’s extensive experience with ICF’s was the perfect fit.  Every single challenge the project presented was overcome with creativity and determination. From the designer, to the engineer, the R-Value Homes staff, and every valued Trade Partner of ours: Thank you for stepping up to the plate to make this incredible home a reality for our clients!” The home is projected to deliver 3,000 kwh’s per year of solar power to the grid, more than what it uses. Sustainability Features 
  • -10 HERS Index Rating
  • Air-to-water Air Source Heat pump for hydronic heating, forced air cooling, and domestic hot water
  • .65 ACH of air leakage Insulated Concrete Form exterior walls (ICFs)
  • Frost Protected Shallow Foundation
  • Polished concrete floors with hydronic heating on both levels
  • Heat Recovery Ventilation exceeding ASHRAE 62.2 2016 Standard
  • Passive Solar Design
  • 100% electrified home
  • Roof-mounted solar PV system is estimated to produce 15 Megawatts a year
  • 27 Kwh Battery System
Check out more photos and details on Houzz
This home and all homes meeting the GreenStar Homes Certification Silver (v3) Feature these items additional green items.
  • Moisture and wall water leak assessment + repair
  • Plumbing leak and pressure test shows no leaks
  • No gas leaks detected after construction / renovations
  • Test for no CO backdrafting from gas appliances
  • No new supply ducts panned in joists
  • Use at least MERV 8 Rated Filters on Ducted Systems
  • Electric stove OR Range Hood tested to vent at 100 CFM outdoors
  • Carbon Monoxide detectors (can be dual smoke) installed on all floors and near fireplaces
  • Use steel braided hoses or drainpans under washers in or above living spaces
  • Drainpans under tank water heaters that are in or above living spaces
  • 90% LEDs used
  • Gutter system draining away from home or well draining sandy soils
  • Bathroom exhaust fans must be tested to at least 50 CFM or more in each bathroom
  • No radon detected above PCL 4 when tested or system installed
  • New HVAC must be properly sized based on manual J/D or equivalent
  • Moisture resistant flooring in bathroom, kitchen & entry ways
  • Whole Home Fresh air supply provided
  • All fireplaces must have proper ventilation per IAP or No fireplace exists
  • Refrigerant charge test completed on all AC / Heat pumps
  • Instructions created documenting how to operate the home or unit
  • New gas appliances must be sealed, vented or ideally electric
  • Homeowner or tenant trained on how to operate the house or unit
  • DOE Home Energy Score of 6
  • Shower head(s) are under 2.0 Gallons Per Minute (Average) or Home Water Score of 3
  • Bathroom Aerators are under 1.75 Gallons Per Minute (Average) or Home Water Score of 3
  • Toilets are under 1.3 Gallons per Flush (average) or Home Water Score of 3
  • Non paper face drywall backer in NEW shower / tub surrounds
  • Don’t use HVAC during construction – Major remodels and new only
  • Insulate hot water lines or have runs 10 feet or shorter to all lines
  • Paint/caulks/sealants/primers must be certified Low VOC or NO VOC
  • Kitchen must have proper ventilation through rangehood or outdoor air system
  • Well water systems must use on demand softeners when present (Gold)
  • Bathroom controls such as timer/occupancy sensor or humidistat (Gold)
  • Balanced fresh air system installed and working
  • Final Grade Slopes Away from Foundation 0.5 inch per foot for 10 feet
  • If installing new wood do not use tropical OR make sure it is certified (gold)
  • Insulate cold water pipes or keep them out of unconditioned space (Gold)
  • DOE Home Energy Score of 10 on existing or 17.5 mbtu/year of energy (Platinum)
  • Water heating is all electric or solar
  • All space heating is electric or solar thermal
  • All water heating is electric or solar thermal
  • No fireplace indoors
  • Indoor air quality test after construction are at or below the WELL Standard.
  • Home breaker box can fit future solar
  • Certified low emitting or sealed edges on new cabinets
  • Floorscore or Green Label Plus on 90% of new Carpet
  • Tap water filtration added that is appropriate to area
  • Shoe removal space with no carpet at main entry
  • Flush out home for 48 hours after construction activity before client move in
  • Add leaf debris filter to gutters
  • No gas or propane hook up connected
  • Induction or electric cooktop
  • Battery storage system
  • Ability to make blue light free lighting in high use rooms
  • Refrigerator has freezer on top or bottom
  • Low duct leakage or no ducts
  • Motion sensor / dimmer lights in high use rooms
  • Energy Star Dishwasher Installed

Recent Posts

DiGiacomo Homes & Renovation: New Home Bronze

May 23, 2024

Members enter in a drawing to win! New Net Zero

May 23, 2024

Clean Energy Credit Union Clean Energy For All Reduces Barriers

May 17, 2024

Categories

Archives

Register a LEED Project

Get the GreenStar Checklist

BuildEquinox

Breath is the bridge which connects life to consciousness.
Visit Website
panasonic-logo

Panasonic

Ventilation for everything you need
Visit Website

Comments are closed.

Become A Member

The GreenHome Institute is a 501(c)3 nonprofit that is funded by members who support the green building movement. Bonus benefits include reduced green certification costs, free continuing education, and more. Become a member today!

Learn More
Green Home Institute Logo 1

The GreenHome Institute is a non-profit organization that empowers people to make healthier and more sustainable choices in the renovation and construction of the places we live.

Read More
  • About
  • Events
  • Sustainable Building
  • Find a Pro
  • Get Involved
  • Join GHI
  • Contact Us
  • About
  • Events
  • Sustainable Building
  • Find a Pro
  • Get Involved
  • Join GHI
  • Contact Us
  • News
  • Privacy Policy
  • Terms & Conditions
  • Make a Donation
  • Become a Member
  • Become a Volunteer
  • Become a Sponsor
  • News
  • Privacy Policy
  • Terms & Conditions
  • Make a Donation
  • Become a Member
  • Become a Volunteer
  • Become a Sponsor

Contact

  • 1451 Lake Drive SE, #6484
Grand Rapids, MI 49516
  • Tel: (616) 458-6733
  • Email: info@greenhomeinstitute.org
  • Copyright © 2023 GreenHome Institute. All rights reserved. Designed by Multiserv.
  • Login
  • Sign Up
Forgot Password?
Lost your password? Please enter your username or email address. You will receive a link to create a new password via email.